• ISA TP-973012

ISA TP-973012

  • Layer of Protection Analysis for Determining Safety Integrity Level
  • standard by The International Society of Automation, 01/01/1997
  • Category: ISA

$12.00 $10.00

Building on the CCPS (Center for Chemical Process Safety) Guidelines for Safe Automation ofChemical Processes, this paper shows how to determine if additional safeguards are needed and how to determine the needed SIL (Safety Integrity Level) of a SIS (Safety Instrumented System). Layer of Protection Analysis (LOPA) is a tool that can be used after the HAZOP (HAZard and Operability Analysis), but before using fault tree analysis or quantitative risk analysis. Using a multi-disciplined team, the consequences identified in the HAZOP are listed as impact events and are classified for severity level. The initiating causes are listed for each impact event and a likelihood is estimated for each initiating cause. Independent Protection Layers (IPLs) are listed, including process design, basic process control system, alarms and procedures, safety instrumented systems, and additional mitigation. Each IPL is assigned a Probability of Failure on Demand (PFD). A mitigated event likelihood is calculated by multiplying the initiating cause likelihood by the PFDs for the applicable IPLs. The mitigated event likelihood is then compared to a criterion linked to the corporation?s criteria for unacceptable risk levels. Additional IPLs can be added to reduce the risk. The mitigated event likelihoods are summed to give an estimate of the risk for the whole process.
PDF

All of our standards document are available in PDF (Portable Document Format), an electronic, downloadable format.You will be able to download the file in your account downloads.

Multi-User Access

After purchasing, you have the ability to assign each license to a specific user.

Printable

At any time, you are permitted to make printed copies for your and your members' reference use.

ISA 12.23.01-1998

ISA 12.23.01-1998

Electrical Apparatus for Use in Class I, Zone 1 Hazardous (Classified) Locations: Type of Protection..

$76.00 $151.00

ISA 12.22.01-1998

ISA 12.22.01-1998

Electrical Apparatus for Use in Class I, Zone 1 Hazardous (Classified) Locations: Type of Protection..

$89.00 $178.00

ISA 12.16.01-1998

ISA 12.16.01-1998

Electrical Apparatus for Use in Class I, Zone 1 Hazardous (Classified) Locations: Type of Protection..

$90.00 $180.00

ISA 12.26.01-1998

ISA 12.26.01-1998

Electrical Apparatus for Use in Class I, Zone 1 Hazardous (Classified) Locations: Type of Protection..

$76.00 $151.00