ULC 770
- Standard Test Method for Determination of Long-term Thermal Resistance of Closed-Cell Thermal Insulating Foams (CAN/ULC S770-15)
- standard by Underwriters Laboratories of Canada, 02/01/2015
- Category: ULC
$253.00
$127.00
This procedure, based on ASTM standard test methods ASTM C1303 and ASTM C518, estimates the change in the thermal resistivity of insulating foam products by means of slicing and scaling.
This procedure addresses faced and unfaced products without consideration to the effect of facers on the LTTR of the product.
This test procedure is applicable to cellular plastic insulation manufactured to retain a gas or mixture of gases, other than air, for a period longer than 180 days. If the thermal resistivity of a product changes by more than 3% over this 180 days period, this test procedure shall be applied. This procedure specifies reference time, sampling and testing requirements to determine LTTR for closed-cell foams such as extruded polystyrene, sprayed polyurethane, and polyisocyanurate.
The changes made to this edition of the Standard include clarifications of the terms "base formulation" and "mean temperature", new Clauses to address the testing of materials thicker than 75 mm and a new section on testing of actual 5 year samples.
All of our standards document are available in PDF (Portable Document Format), an electronic, downloadable format.You will be able to download the file in your account downloads.
After purchasing, you have the ability to assign each license to a specific user.
At any time, you are permitted to make printed copies for your and your members' reference use.