UOP 766-13
- Piece Density by Mercury Displacement
- standard by UOP LLC, A Honeywell Company, 06/01/2013
- Category: UOP
$240.00
$120.00
This method is for determining the piece density (mass per unit volume) of particulate solids by mercury displacement. The method is applicable to catalyst supports and granular material ranging in size from 0.6 mm (30 mesh) to 5 mm (3 mesh) or powders in the range of 0.6 mm to 0.15 mm (100 mesh). Void space between particles is not included in the volume. Internal pores having diameters less than approximately 12 µm are included in the volume; larger pores are not. The piece density is reported as g/mL.
All of our standards document are available in PDF (Portable Document Format), an electronic, downloadable format.You will be able to download the file in your account downloads.
After purchasing, you have the ability to assign each license to a specific user.
At any time, you are permitted to make printed copies for your and your members' reference use.