• UOP 842-83

UOP 842-83

  • Nickel, Iron, Sulfur and Vanadium in Distillate, Residual Oils and Pitches by XRF
  • standard by UOP LLC, A Honeywell Company, 01/01/1983
  • Category: UOP

$287.00 $144.00

This rapid, nondestructive method is for determining nickel, iron and vanadium in distillate and residual oils and nickel, iron, vanadium and sulfur in solid pitches by energy dispersive x-ray fluorescence (XRF). The lower limit of detection for nickel, iron and vanadium is 2 mass-ppm. The lower limit of detection for sulfur in pitches is 100 mass-ppm.

The method assumes a linear relationship of percent metal vs. intensity when the concentration of the metal in the standards closely brackets the unknown. It also assumes that corrections for matrix absorption or inter-element effects are not required when properly calibrated standards of similar composition are used. Samples which are not homogeneous or that contain particulate material that precipitates on standing are not applicable.

The method is written for use with Kevex Model 0700-7000 Energy Dispersive instrument, however, other equivalent equipment is satisfactory.

PDF

All of our standards document are available in PDF (Portable Document Format), an electronic, downloadable format.You will be able to download the file in your account downloads.

Multi-User Access

After purchasing, you have the ability to assign each license to a specific user.

Printable

At any time, you are permitted to make printed copies for your and your members' reference use.

UOP 772-77

UOP 772-77

Mercaptan Sulfur in LPG by Microcoulometry..

$144.00 $287.00

UOP 777-77

UOP 777-77

Hydrocarbon Types in Petroleum Fractions by Chromatography..

$144.00 $287.00

UOP 792-78

UOP 792-78

The Colorimetric Determination of Silica in Aqueous Solutions..

$144.00 $287.00

UOP 606-78

UOP 606-78

Chloride in Hydrocarbons by Oxy-Hydrogen Combustion..

$144.00 $287.00