• UOP 999-13

UOP 999-13

  • Precision Statements in UOP Methods
  • standard by UOP LLC, A Honeywell Company, 12/01/2013
  • Category: UOP

$240.00 $120.00

This method is for developing precision statements as reported in UOP methods and relative bias of the same method between different laboratories. The calculation of precision, in terms of repeatability and intermediate precision (within a laboratory), reproducibility (between laboratories) and relative bias (between laboratories) is described. Precision statements in methods having a 98 or later suffix were developed by the procedure described; methods having an 88 through 97 suffix used UOP 888-88, while methods with suffixes earlier than 88 used UOP 666-82.

The features of UOP 999 are as follows:

Minimum of 16 analyses required with emphasis on multiple concentration levels
Better identification of the components of variation and repeatability estimates
Alignment with ASTM repeatability, intermediate precision, and reproducibility definitions
Relative bias between laboratories with 95% confidence interval

UOP 999 is the minimum guideline for estimating the initial precision for new or revised methods. Once a new or revised method is in use, a reference sample, if available, should be run on a regular basis. When 16 analyses have been completed, individual and range control charts are to be used to estimate the long-term UOP repeatability and are to be maintained on an ongoing basis. The example calculations in UOP 999 are made using Minitabâ, a statistical software package. The details of the calculations are in UOP 999-97 Supplement.

PDF

All of our standards document are available in PDF (Portable Document Format), an electronic, downloadable format.You will be able to download the file in your account downloads.

Multi-User Access

After purchasing, you have the ability to assign each license to a specific user.

Printable

At any time, you are permitted to make printed copies for your and your members' reference use.

UOP 778-07

UOP 778-07

Packed Apparent Bulk Density (ABD) of Extruded Catalyst..

$120.00 $240.00

UOP 905-08

UOP 905-08

Platinum Agglomeration by X-Ray Diffraction..

$120.00 $240.00

UOP 880-08

UOP 880-08

Hydrocarbon Types and Distributions in Low Olefin C12 and Lower Endpoint Distillates by GC..

$120.00 $240.00

UOP 551-08

UOP 551-08

C6 and Lower Boiling Hydrocarbons in Olefin Free Naphthas by GC..

$120.00 $240.00